Connecting XP400 Pro to IM508 gives error "No connect to programmer"

Customer Problem: I wanted to use XP400 Pro to add a key to an EWS3. When it is connected to the IM508 tablet it is not recognized and always 0 volts while the a2 Volt is connected to the XP400. Solution: Please do the below action. (need xp400pro) 1. Enter the BMW EWS3 path of the programmer to try to read and write; 2. Check whether the adapter board pins correspond to the EWS3 slots accurately; 3. Operate in strict accordance with the operating instructions. Step 1: Connect the matching board and EWS3 module first. Step 2: Connect the board and XP400 PRO. Step 3: USB connect XP400 PRO and tablet. Step 4: Connect the 12V power supply to the XP400 PRO; note that the power of the IM508 must be more than 30%. Step 5: Open the menu and execute the read function. Step 6: If the 12V is not connected, and the function is executed directly, the USB port will hang up and cannot be used. In this case, please restart the tablet, the USB port is enabled, and communication can be performed nor...

VW Golf MK7 2018 Add a Key via Autel IM608 + XP400 Pro

Autel MaxiIM IM608 + XP400 Pro key programmer supports to add key for Volkswagen Golf MK7 2018, it can also perform all key lost, read password, remote learning for VW vehicles as below: VW(EU) Car List: Vehicle Model Year System Add Key All Key Lost Read Password Remote Learning Golf 1998-2007 IMMO3 INS Part support by OBD Part support by OBD Part support by OBD All support by OBD Golf 2004-2009 IMMO4 CAN INS Part support by OBD × Part support by OBD All support by OBD Golf 2009-2013 IMMO4 CAN INS All support by OBD All support by OBD All support by OBD All support by OBD Golf 2013- MQB INS All support by OBD All support by OBD All s...